Siemens SIMATIC RF185C Operating Instructions Manual page 70

Hide thumbs Also See for SIMATIC RF185C:
Table of Contents

Advertisement

Configuring with the WBM
7.3 The menu items of the WBM
Figure 7-8
The "Settings - Communication" menu item, "OPC UA" tab
Basic settings
In the "OPC UA" area you can make the basic settings for the OPC UA interface. Select the
"Interlock OPC" check box to disable the OPC UA interface.
Table 7- 8
Parameter
Application name
Minimum
sampling interval
70
Description of the parameters
Description
Name of the OPC UA application of the server. The application name is re-
quired to identify the OPC UA namespace of the communications module and
should be unique for each communications module within the project.
The application name is part of the URL of the OPC UA server of the commu-
nications module.
Minimum sampling interval at which the communications module samples the
process data.
Range of values: 10 .. 50 ms
Default setting: 50 ms
SIMATIC RF185C, RF186C, RF188C
Operating Instructions, 10/2018, C79000-G8976-C512-01