AutoId
OPC UA
status
status
19
good
19
good
19
good
20
good
20
good
--
--
--
OpcUa_
BadInva-
lidState
--
OpcUa_
BadOutOf
Range /
OpcUa_
Bad
Configura-
tion
Error
--
BadInvalid
Argument
--
BadInvalid
Argument
--
BadInvalid
Argument
--
BadInvalid
Argument
--
Bad
SIMATIC RF185C, RF186C, RF188C
Operating Instructions, 10/2018, C79000-G8976-C512-01
AutoId
text
RF_COMMUNICATION_
ERROR
RF_COMMUNICATION_
ERROR
RF_COMMUNICATION_
ERROR
DEVICE_FAULT
DEVICE_FAULT
--
--
--
--
--
--
--
--
Error description
The selected frequency is not enabled.
The carrier signal is not activated.
General radio protocol error
Fault in power supply
The power supply is very close to the low limit.
Antenna errors
The antenna or the antenna cable is defective.
•
Error in the connection to the reader; the reader is not an-
•
swering (in PROFIBUS operation).
–
The cable between the communications module and
reader is wired incorrectly or there is a cable break
–
The 24 V supply voltage is not connected or is turned off
or has failed briefly
–
Automatic fuse on the communications module has
blown
–
Hardware defective
–
Another reader is in the vicinity and is active
–
There is a reflecting metal surface in the vicinity that is
disrupting the antenna field
–
Execute "init_run" after correcting the error
The selected antenna is not enabled.
The command is not permitted in this status or is not supported.
Possible cause:
"INIT" was chained.
•
Command repetition was started without "Presence mode".
•
No or bad configuration data/parameters were transferred.
Possible cause:
You are accessing a read point that is not configured.
•
A parameter is missing.
The parameter has an invalid format.
The parameter type is invalid.
Unknown parameter.
The command or the frame has an invalid format.
Service and maintenance
10.2 Error messages
133