Parameter
User mode
Transmission
speed
Reader parameters
This area shows the reset parameters of the reader connected to the interface in
hexadecimal format.
Depending on the set basic parameters, you can configure the following reader parameters
in the "Reader parameters" parameter group.
Table 7- 5
Parameters in the "Reader parameters" parameter group
Parameter
Presence check
Reset error LED
HF power
1)
SIMATIC RF185C, RF186C, RF188C
Operating Instructions, 10/2018, C79000-G8976-C512-01
Parameter value
Ident profile/RFID stand-
ard profile
FB 45
19.2 kBd
57.6 kBd
115.2 kBd
Parameter value
On
Off (RF field on)
Off (RF field off)
On
Off
0.50 ... 5.00
Default value
Description
Ident profile/RFID
Shows which block has been set in STEP 7:
standard profile
115.2 kBd
Selection depends on the Ident system being
used. With this parameter, you set the data
transmission speed between the communica-
tions module and reader.
When an optical reader is connected: The
transmission speed selected here must match
the transmission speed selected in the firmware
of the reader.
Default value
Description
On
On = As soon as there is a transponder in the
antenna field of the reader, its presence is re-
ported.
Off (RF field on) = the presence check in the FB
is suppressed. The antenna on the reader is
nevertheless turned on as long as it has not
been turned off by a command.
Off (RF field off) = the antenna is turned on only
when a command is sent and it then turns itself
off again.
On
On = The flashing of the error LED on the read-
er is reset by each reset and by a new OPC
command.
Off = the error LED always indicates the last
error. The display can only be reset by turning
off the reader.
1.00
Setting for the output power of the reader.
1.25
The selectable values depend on the connected
device.
Configuring with the WBM
7.3 The menu items of the WBM
Ident profile/RFID standard profile:
The program block for the Ident profile/RFID
standard profile is used on the controller.
FB 45:
Single tag mode. FB 45
(PROFIBUS/PROFINET) is used in the con-
troller.
65