Configuring
6.2 Configuration via PROFINET IO
Parameter group "Module parameters" of the connected readers
In this parameter group, you can configure all module-specific parameters of the connected
readers.
Table 6- 4
Parameters of the parameter group "Module parameters" of the connected readers
Parameter
User mode
MOBY mode
Transmission
speed
Diagnostics
messages
50
Parameter value
RFID standard profile
FB 45
RF200/RF300/RF600;
MV400/MV500; MOBY
U/D normal addr.
19.2 kBd
57.6 kBd
115.2 kBd
None
Hard errors
Hard/soft errors
Default value
Description
RFID standard pro-
With this parameter, you select the block:
file
RF200/RF300/RF60
With this parameter, you set the mode of the
0; MV400/MV500;
communications module.
MOBY U/D normal
addr.
Normal addressing: The transponder is ad-
dressed with physical addresses.
115.2 kBd
With this parameter, you set the data transmis-
sion speed between the communications mod-
ule and reader.
When an optical reader is connected: The
transmission speed selected here must match
the transmission speed selected for the reader.
None
With this parameter, you determine the extent
to which the reader-related diagnostic interrupt
messages are to be reported.
Operating Instructions, 10/2018, C79000-G8976-C512-01
RFID standard profile:
The program block for the Ident profile is
used in the controller.
FB 45:
Single tag mode. FB 45 is used in the con-
troller
RF200/RF300/RF600; MOBY U/D normal
addr.
None:
No alarms are generated.
Hard errors:
Critical hardware errors/faults are reported
by the S7 diagnostics.
Hard/soft errors:
Critical hardware faults and errors occurring
when processing commands are reported
by the S7 diagnostics.