Diagnostics - Logbook
These variables supply various log information of the RF18xC communications module.
Table 9- 21
Path
Data type
Access
Description
Possible values
Table 9- 22
Path
Data type
Access
Description
Possible values
9.2.6

DigitalIOPorts

These variables are used to query and set the digital inputs and outputs of the RF18xCI
communications module.
SIMATIC RF185C, RF186C, RF188C
Operating Instructions, 10/2018, C79000-G8976-C512-01
LastLogEntry
Root/Objects/DeviceSet/Read_point_x/RuntimeParameters/Diag
nosis/Logbook/LastLogEntry
String
R
Log diagnostics
The last entry in the log is output.
The prerequisite is that the "Parallel" or "Diagnostics" option is
set in the WBM.
Example:
2018-05-30T13:14:43.546+00:00 | COMMANDS | readTagIDs |
CMD | 0 | Readpoint_11 | 000000005575B67D | PC=0000 |
RSSI=0 | Pwr=0
LogColumns
Root/Objects/DeviceSet/Read_point_x/RuntimeParameters/Diag
nosis/Logbook/LogColumns
String
R
Log diagnostics
The headers column of the RF18xC log is output as formatted
string. The individual fields are separated by semicolons.
The prerequisite is that the "Parallel" or "Diagnostics" option is
set in the WBM.
Date_Time ; Type ; Entry ; Command_Type; Sequence_Number ;
Readpoint ; EPCID_UID ; PC ; RSSI ; Power
Programming via the OPC UA interface
9.2 OPC UA variables