7 TESTING
Table 7–7: 120 Ω NICKEL TEST
EXPECTED RTD
APPLIED
TEMPERATURE READING
RESISTANCE
120 Ω NICKEL
° CELSIUS
86.17 Ω
–50°C
120.00 Ω
0°C
157.74 Ω
50°C
200.64 Ω
100°C
248.95 Ω
150°C
303.46 Ω
200°C
366.53 Ω
250°C
Table 7–8: 100 Ω NICKEL TEST
EXPECTED RTD
APPLIED
TEMPERATURE READING
RESISTANCE
100 Ω NICKEL
° CELSIUS
71.81 Ω
–50°C
100.00 Ω
0°C
131.45 Ω
50°C
167.20 Ω
100°C
207.45 Ω
150°C
252.88 Ω
200°C
305.44 Ω
250°C
Table 7–9: 10 Ω COPPER TEST
EXPECTED RTD
APPLIED
TEMPERATURE READING
RESISTANCE
10 Ω COPPER
° CELSIUS
7.10 Ω
–50°C
9.04 Ω
0°C
10.97 Ω
50°C
12.90 Ω
100°C
14.83 Ω
150°C
16.78 Ω
200°C
18.73 Ω
250°C
GE Power Management
° FAHRENHEIT
1
2
–58°F
32°F
122°F
212°F
302°F
392°F
482°F
° FAHRENHEIT
1
2
–58°F
32°F
122°F
212°F
302°F
392°F
482°F
° FAHRENHEIT
1
2
–58°F
32°F
122°F
212°F
302°F
392°F
482°F
469 Motor Management Relay
7.2 HARDWARE FUNCTIONAL TESTING
MEASURED RTD TEMPERATURE
SELECT ONE: ____( °C ) ____( °F )
3
4
5
6
7
MEASURED RTD TEMPERATURE
SELECT ONE: ____( °C ) ____( °F )
3
4
5
6
7
MEASURED RTD TEMPERATURE
SELECT ONE: ____( °C ) ____( °F )
3
4
5
6
7
8
9
10
11
12
8
9
10
11
12
8
9
10
11
12
7-5