7 TESTING
3. Verify the ammeter readings as well as the measured analog input readings. For the purposes of testing,
the analog input is fed in from the analog output (see Figure 7–1: SECONDARY INJECTION TEST
SETUP). View the measured values in:
A2 METERING DATA\ANALOG INPUTS
Table 7–11: ANALOG I/O TEST 4-20 mA
ANALOG
EXPECTED
OUTPUT
AMMETER
FORCE
READING
VALUE
0%
4 mA
25%
8 mA
50%
12 mA
75%
16 mA
100%
20 mA
b) 0-1 mA
1. Alter the following setpoints:
S12 ANALOG I/O\ANALOG INPUT1\ANALOG INPUT1: 0-1 mA
S12 ANALOG I/O\ANALOG INPUT1\ANALOG INPUT1 MINIMUM: 0
S12 ANALOG I/O\ANALOG INPUT1\ANALOG INPUT1 MAXIMUM: 1000 (repeat for analog inputs 2 to 4)
2. Analog output values should be ±0.01 mA on the ammeter. Measured analog input values should be ±10
units. Force the analog outputs using the following setpoints:
S13 TESTING\TEST ANALOG OUTPUT\FORCE ANALOG OUTPUTS FUNCTION: Enabled
S13 TESTING\TEST ANALOG OUTPUT\ANALOG OUTPUT 1 FORCED VALUE: 0%
(enter desired percent, repeats for analog output 2-4)
3. Verify the ammeter readings as well as the measured analog input readings. View the measured values in:
A2 METERING DATA\ANALOG INPUTS
Table 7–12: ANALOG I/O TEST 0-1 mA
ANALOG
EXPECTED
OUTPUT
AMMETER
FORCE
READING
VALUE
0%
0 mA
25%
0.25 mA
50%
0.50 mA
75%
0.75 mA
100%
1.00 mA
GE Power Management
MEASURED AMMETER
READING (mA)
1
2
3
4
MEASURED AMMETER
READING (mA)
1
2
3
4
469 Motor Management Relay
7.2 HARDWARE FUNCTIONAL TESTING
EXPECTED
MEASURED ANALOG INPUT
ANALOG
READING (units)
INPUT
1
2
READING
0 mA
250 mA
500 mA
750 mA
1000 mA
EXPECTED
MEASURED ANALOG INPUT
ANALOG
READING (units)
INPUT
1
2
READING
0 mA
250 mA
500 mA
750 mA
1000 mA
3
4
7
3
4
7-7