Menu 2.3 Variable Rate Application (VRA) / Remote / HARDI® AutoSectionControl
If the volume rate is to come from an external source (e.g. a site specific application map, remote sensor or a GPS system like
HARDI® AutoSectionControl), this menu has to be enabled. This is done by selecting one of the submenus:
• Menu 2.3.1 Disable
• Menu 2.3.2 Enable
The
symbol on the 1st line in the display will be visible. Manual pressure regulation and stepped over/under application
is still possible.

Menu 2.4 Set clock

If the Controller prompts for date and time, then set clock to enable register.
This must be done before the Controller is put into operation for the first time, otherwise no start and stop time will be
recorded in the registers. Later changes in date and time can be done by following the procedure in "How to set clock" on
page 4.2.
ATTENTION! If no prompt, the dealer may already have done this.
In submenus it is possible to select and set:
Menu
Function
2.4.1
Time format (12 or 24 hour)
2.4.1.1
12 hour format
2.4.1.2
24 hour format
2.4.2
Set time
2.4.3
Set date and month
2.4.4
Set year

Menu 2.5 Alarms

User selectable alarms can be set with parameters of choices given in
the submenus of menu 2.5 - refer to "Full menu structure" on page 3.15
for available alarms.
• When outside the alarm parameters, the relevant warning will flash
lower left corner of the screen.
• Volume rate alarm for over or under application activates after 20
seconds.
The warnings appear as shown. For more details on warnings, see "Fault
codes" on page 11.5.
÷
NOTE! The HC 9500 shows the warnings in the top bar of the
screen. Other ISOBUS screens may vary.
6 - Menu 2 Setup