Automatic Swath Control (AutoSectionControl)

Automatic Swath Control
The Automatic Swath Control feature turns
sections off and on automatically based upon the
following conditions:
• Entering and exiting internal and outer field
boundaries.
• Entering and exiting previously-applied areas
within a field.
At the Configuration Setup screen, press the
Automatic Swath Control button. At the screen
that appears, options are:
• Outside Boundary Option
Select one of the two options to determine
system behavior when a section exits a field
boundary.
• Coverage Option
In the Coverage Option area, you must
choose between three options:
• Minimize Skip
Turns off the implement section after the entire section is fully inside your coverage area.
This prevents the possibility of skips.
• Minimize Overlap
Turns off the implement section when that section first enters your coverage area.
This prevents the possibility of overlaps.
• User Defined
Allows you to choose what percentage of the implement section is within the coverage area before that section
turns off. For example, if you choose 50%, then the section will switch off when half of it is within your coverage
area.
• Turn-On Look Ahead
Determines how far ahead the system looks
to turn the sections back on. This
compensates for delay in the system when
the sprayer sections are turned on.
• Turn-Off Look Ahead
Determines how far ahead the system looks
to turn the sections off. This compensates for
delay in the system when the sections are
turned off.
Your Specific
Configuration
Configuration
Automatic Swath Control
Application
Outside Boundary Option
Keep Unchanged
Turn Section Off
Look Ahead Settings
4 - System setup
Coverage Option
Look-Ahead
Settings
Minimize Skip
Minimize Overlap
User Defined
Turn-On:
Turn-Off: