Functions

Auto functions general info

The Soft key buttons are used for the End Nozzle functions.
ATTENTION! Refer to "B. Soft keys" on page 3.6 for information about how to enter the soft keys.

End nozzles (Fence line) (optional)

If End nozzles/Bi-jet are fitted, set the value to the equivalent coverage by the boom nozzles. E.g. End nozzle coverage is 5
feet. This is equal to [03 Boom nozzles]. Choose End Nozzles by pressing F1.
• When end nozzle is active, it will be shown in the display with two icons at the ends of the boom line.
• Set up of end nozzles/Bi-jet can be done from menu 3.3.4.
ATTENTION! It is important that the volume applied from the end nozzle or Bi-jet matches the volume applied under
the boom. This is a comparison of volume per minute per length. (Liter/min/meter).
When the end nozzle or Bi-jet is active, the area covered and volume sprayed is calculated and registered. If "Active
boom size" is displayed, it will show an increase when the end nozzle or Bi-jet is activated.