6 - Menu 2 Setup
Menu 2.2 Auto functions
Menu 2.2.1 ON/OFF
The Controller can be set to open the main ON/OFF function above a certain speed and close it below the same speed.
This allows the user to concentrate on driving. If the speed is set at zero, the function is deactivated. Suggested speed
setting is spraying speed less 20%.
When the Auto ON/OFF is active and the main switch and boom section switches are on, the boom status symbol on the
1st line will blink when speed is under the trigger value.
WARNING! Remember to set the main ON/OFF switch to OFF before leaving the field, otherwise the main ON/OFF
will open under transport.
Menu 2.2.2 Foam Marker
The Controller can be set to operate the HARDI® Foam marker automatically through the main ON/OFF valve. When the
main ON/OFF is ON, it will automatically start the Foam marker.
Furthermore, the Foam marker can be set for up and back spraying or race-track (round and round) spraying.
Setting Activity
[Disable]
[Same side]
[Change side]
Foam marker status is shown briefly on the line 4 of the screen.
Menu 2.2.3 Dual line (not used in North America)
This menu is not used in North America.
Menu 2.3 Variable Rate Application
Variable Rate Application (VRA) / Remote
If the volume rate is to come from an external source (e.g. a site specific application map or a remote sensor), this menu
has to be enabled.
The Œ symbol on the 1st line is now visible. Manual pressure regulation and stepped over/under application is still pos-
sible.
The external source is connected to the COM 1 or COM 2 via a 9 pin sub D connector.
ATTENTION! The COM port may have to be set up in the extended menu. Contact your HARDI® service center.
6.2
The marker will only follow the setting of the switch on the Spray Box.
The Controller will automatically activate the same side for race-track spraying.
The Controller will automatically change side for up and back spraying.