Menu 4.7 Emergency

This menu bypasses the system so all sensors are ignored. Then it is possible to align the sprayer or fold the boom manually
and drive home. The sensor status and voltages can be checked, which is useful for HARDI® service to solve the problem.
Menu 4.7.1 Track align
The sensor status and voltages can be checked when aligning the
sprayer.
÷
NOTE! Values shown in illustration is an example only.
Menu 4.7.2 Boom fold
The sensor status and voltages can be checked when folding the boom.
÷
NOTE! Values shown in illustration is an example only.
Lock sensor:
Lock sensor indication
Released (high voltage)
Locked (low voltage)
If the track selection switch is switched to "align" the trapeze lock is attempted locked disregard any sensor reading. No
automatic align is attempted. Manual or automatic tracking is not possible.
Once the boom is folded into transport position, exit the menu. This will activate the track lock if it is not damaged. As an
extra security, stop oil flow to the sprayer and switch power to OFF on the SetBox in order to turn off the JobCom.
DANGER! Emergency only. Don't track with the boom folded! Safety system is disabled.

Menu 4.8 Computer CAN status

In this menu you can see if there is communication between the units, Controller, Jobcom and Track. See part "Emergency
operation".
Menu 4.8.X Computer CAN status:
[4.8.1 Operating status all computer]
[4.8.2 Software versions all computer]
[4.8.3 Hardware versions all computer]
[4.8.4 Work status Terminal HC 6500]
[4.8.5 Work status JobCom HC 6100]
[4.8.6 Work status Grip HC 6300]
[4.8.7 Work status SetBox HC 6400]
[4.8.8 Work status FluidBox HC 6200]
Track selection switch
Auto or Manual
Auto or Manual
Show operating status details in case of faults.
Show software versions details in case of faults.
Show hardware versions details in case of faults.
Show faults occurred since power-up.
Show faults occurred since power-up.
Show faults occurred since power-up.
Show faults occurred since power-up.
Show faults occurred since power-up.
8 - Menu 4 Toolbox
Left/right steer
Possible
Not possible
Press Clear key to reset counters.
Press
key to reset counters.
Press
key to reset counters.
Press
key to reset counters.
Press
key to reset counters.
Fold inner
Possible
Possible
Not for ISOBUS
Not for ISOBUS
Not for ISOBUS
Not for ISOBUS
8.3