Testing Flow Transducer; Testing Speed Transducer - Hardi ISOBUS VT Operator's Manual

The sprayer
Table of Contents

Advertisement

12 - Testing and fine tuning

Testing flow transducer

• BROWN wire to positive of 12 volt battery.
• BLACK wire to negative.
• BLUE wire to multimeter positive.
1. Check the rotor turns freely.
2. Each vane in the rotor has a magnet in it with the pole facing out. Check that the 4 magnets are present.
3. Use a magnet to check that every second magnet in the rotor has the same pole orientation. The rotor magnets must
be N - S - N - S.
4. Connect negative from multimeter to negative of battery.
5. Set multimeter to DC volt.
6. By turning the mill wheel slowly, this will register approximately 8.0 +/- 1 volt with the diode on and 0.3 +/- 0.1 volt
with the diode off with every second magnet.

Testing speed transducer

This transducer is used for speed, Twin speed, Boom fold, SafeTrack, Main pump/FlexCapacity RPM.
• BROWN wire to positive of 12 volt battery.
• BLACK wire to negative.
• BLUE wire to multimeter.
1. Connect negative from multimeter to negative of battery.
2. Set multimeter to DC volt.
3. Bring a metallic object within 1/8" to 3/16" (3 to 5 mm) from the transducer. This will register 1.4 +/- 0.2 volt and the
diode will turn on.
4. By removing the object, this will register 12.0 +/- 1.0 volt. Diode is OFF.
12.2