Control Via Remote Contacts - BONFIGLIOLI ACTIVE Manual

Profibus-dp, communication module cm-pdp, frequency inverter 230v/400v
Hide thumbs Also See for ACTIVE:
Table of Contents

Advertisement

Note:
If transition 5 has been triggered with
control word is only accepted after the completion of the transition process. The
change of state from "Operation enabled" to "Ready" is done after the expiry of the
time
If the parameter
can be set back to 0x0F during the stoppage of the drive. In this way, the drive runs
back up to its set reference value and remains in the state "Operation enabled".
The change of state from "Operation enabled" to "Ready" is done after the set switch-
off threshold has been reached and expiry of the set holding time (equivalent to the
behavior in a quick stop). In this, the parameters
fmax) and
relevant.
10.2.4
In the operation mode
frequency inverter is controlled via the control word in PZD1, with the bits 0 to 5 cor-
responding to the contact inputs S1IND to S6IND. In addition, two virtual contact
inputs S7IND and S8IND are available. These virtual contact inputs are not supported
as a standard feature and are reserved for special applications. In the use of the re-
mote contact, the frequency inverter behaves in the same way as in control via the
hardware contact inputs. The meaning of these inputs can be seen from the operating
instructions.
Note:
State machine:
The values in the states report the feedback message via the state word (Bit 0 to 6) in
PZD1.
06/05
06/05
The default value for the parameter
mode "2 – Ramp". For configurations with torque control, the default
value is operation mode "0 - Coast to stop". In a switch-over of the con-
figuration, the setting value for
necessary.
Braking time
632 parameterized for the DC brake.
State transition 5
Holding time
638 (holding time after switch-off threshold reached) are

Control via remote contacts

Local/Remote
Release is only possible if the hardware release is available via digital
input S1IND.
Power on
Initialisation
Ready
0x23
Enable
on
Operation
enabled
0x27
State transition 5
State transition 5
State transition 5
392 = "2 - Ramp" has been set, the control word
Switch-off threshold
412 = "2 - Control via remote contacts" the
Quitt fault
Enable
off
392 is operation
392 is also altered if
392 = "1 - DC brake", a new
637 (percent of
Fault
0x08
from any state
25