Via the parameter
Active data set
independent of whether the data set change-over has been done via control inputs or
via
10.2.2
In the operation mode control via contacts (
inverter is controlled via the contact inputs S2IND to S6IND. The meaning of these
inputs can be seen from the operating instructions. The control word in PZD1 is not
relevant for this operation mode.
State machine:
The values contained in the states report the feedback about the state word (Bit 0 to
Bit 6) in PZD1.
20
20
Active data set
249 states the activated data set with the value 1, 2, 3 or 4. This is
Data set selection
414.
Control via contacts
Power on
Initialisation
Ready
0x23
Enable
on
Operation
enabled
0x27
Control word
Bit No.
Name
0
1
-
2
-
3
-
4
-
5
-
6
-
7
-
8
-
9
-
10
-
11
-
IW1
chapter 10.2.6
12
13
IW2
chapter 10.2.6
14
IW3
chapter 10.2.6
15
-
249 the data set currently selected can be read out.
Local/Remote
Quitt fault
Enable
off
Bit No.
-
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
412 = 0) the frequency
Fault
0x08
from any state
State word
Name
Ready to switch on
Ready
Operation enabled
Fault
Voltage -inhibited
Quick-stop
Switch on inhibit
Warning
-
Remote
Reference value reached
Limit value reached
IW1
chapter 10.2.6
IW2
chapter 10.2.6
IW3
chapter 10.2.6
Warning 2
06/05
06/05