Control Via Remote Contacts - BONFIGLIOLI ACTIVE Manual

Canopen communication module cm-can, 230v/400v
Hide thumbs Also See for ACTIVE:
Table of Contents

Advertisement

9.3
In the operation mode
frequency inverter is controlled via the control word, with the bits 0 to 5
corresponding to the contact inputs S1IND to S6IND. In addition, two virtual contact
inputs S7IND and S8IND are available. These virtual contact inputs are not supported
as a standard feature and are reserved for special applications. In the use of the
remote contact, the frequency inverter behaves in the same way as in control via the
hardware contact inputs. The meaning of these inputs can be seen from the operating
instructions.
Note:
State machine:
The values in the states report the feedback message via the state word (Bit 0 to 6).
Note:
06/05
06/05

Control via remote contacts

Local/Remote
Release is only possible if the hardware release is available via digital
input S1IND.
Power on
Initialisation
Ready
0x23
Enable
Enable
off
on
Operation
enabled
0x27
The inputs set via the control word can be observed with the help of
Digital Inputs
parameter
being set if the hardware release is available and the control word / Bit 0
has been set.
If the data set switch-over is used, please make sure that the parameter
Local/Remote
412 is set to operation mode "2 - Control via remote
contacts" in all the data sets used.
412 = "2 - Control via remote contacts" the
Quitt fault
from any state
250. Digital input S1IND is only displayed as
Fault
0x08
41
41