Table A-1. ENV Command Parameters (Continued)
ENV Parameter and Options
Slave Enable #2 [Y/N]
Slave Starting Address #2
Slave Ending Address #2
Slave Address Translation
Address #2
Slave Address Translation
Select #2
Slave Control #2
Master Enable #1 [Y/N]
Master Starting Address #1
Master Ending Address #1
http://www.mcg.mot.com/literature
Configure and Environment Commands
Default
N
Do not setup and enable the Slave Address
Decoder #2.
00000000
Base address of the local resource that is
accessible by the VMEbus. Default is 0.
00000000
Ending address of the local resource that is
accessible by the VMEbus. Default is 0.
00000000
Works the same as Slave Address Translation
Address #1. Default is 0.
00000000
Works the same as Slave Address Translation
Select #1. Default is 0.
0000
Defines the access restriction for the address
space defined with this slave address decoder.
Default is $0000.
Y
Yes, setup and enable the Master Address
Decoder #1.
02000000
Base address of the VMEbus resource that is
accessible from the local bus. Default is the end
of calculated local memory, unless memory is
less than 16MB, then this register will always
be set to 01000000.
EFFFFFFF Ending address of the VMEbus resource that is
accessible from the local bus. Default is the end
of calculated memory.