10.6 Connection Methods
10.6.1.2

DRIVE-CLiQ signal cables without 24 V DC cores

Pre-assembled DRIVE-CLiQ signal cables without 24 V DC cores are used to connect
components with DRIVE-CLiQ connection, which have a separate or external 24 V DC
power supply. They are mainly intended for use in control cabinets. The signal cables are
available with RJ45 connectors in degrees of protection IP20 and IP67.
Table 10- 7
DRIVE-CLiQ bridge
50 mm
100 mm
150 mm
200 mm
250 mm
300 mm
350 mm
Cable length without connector
1)
Cable lengths from 600 mm and higher are used to connect to other applications (e.g.
establish a 2nd line in the drive line-up, establish wiring in a star configuration etc. )
Figure 10-3
10.6.1.3

DRIVE-CLiQ signal cables MOTION-CONNECT with DRIVE-CLiQ connectors

The MOTION-CONNECT DRIVE-CLiQ signal cables with DRIVE-CLiQ connectors have 24
V DC cores. They are used for components with DRIVE-CLiQ connection if higher
requirements must be complied with, such as mechanical stress and resistance to oil. For
example, the signal cables are used for connections outside the control cabinet
The maximum length of the DRIVE-CLiQ MOTION-CONNECT signal cables with DRIVE-
CLiQ connectors is:
● 100 m for MOTION-CONNECT 500 cables
● 75 m for MOTION-CONNECT 800PLUS cables
The signal cables are available in degrees of protection IP20 and IP67.
362
Actual cable lengths of DRIVE-CLiQ bridges
DRIVE-CLiQ signal cables without 24 V DC cores (IP20)
Cable length L
1)
110 mm
160 mm
210 mm
260 mm
310 mm
360 mm
410 mm
Manual, (GH6), 07/2016, 6SL3097-4AL00-0BP5