8.3.5

Dimension drawing

Figure 8-25
8.3.6

Mounting

Safe Brake Adapter
The Safe Brake Adapter is designed for mounting on a rail in accordance with EN 60715
Housing cover after replacing the fuse
An adhesive label is provided on the housing cover indicating the position of the connector.
You should attach the housing cover so that the labeling on the label matches the
connectors.
8.3.7

Technical data

Table 8- 29
Technical data
6SL3355-2DX00-1AA0
Electronics power supply
(power supply via the Control Interface Module)
Power supply
Motor holding brake
Current consumption, max.
Motor holding brake
Fast de-energization
Weight
AC Drive
Manual, (GH6), 07/2016, 6SL3097-4AL00-0BP5
Supplementary system components and encoder system integration
Dimension drawing of Safe Brake Adapter, all data in mm and (inches)
8.3 Safe Brake Adapter optional module
Unit
Value
V
24 (20.4 ... 28.8)
DC
V
230
AC
A
2
A
2
kg
0.25
333