7.3 Control Unit CU310-2 PN (PROFINET)
7.3.2.15

RESET button

Pressing the RESET button restarts the CU310-2 PN after expiry of a preset time. A data
backup is run at the same time. This means that all the settings are retained.
7.3.2.16

Memory card

Inserting the memory card
Use only memory cards manufactured by Siemens to run the CU310-2 PN.
Insert the memory card into the CU310-2 PN so that the arrow on the card's label (on the
left, next to the word Siemens) points to the arrow on the device.
Figure 7-5
The memory card in a faulty CU310-2 PN
If you are returning a faulty CU310-2 PN to Siemens, remove the memory card and keep it in
a safe place.
This ensures that all your saved data (firmware, licenses, parameters) will be available to
you immediately again to commission a replacement unit.
238
CU310-2 PN Inserting the memory card
Manual, (GH6), 07/2016, 6SL3097-4AL00-0BP5