Mounting - Siemens SINAMICS S120 Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Mains connection and line-side power components
3.7 Line filter
3.7.5

Mounting

External line filters for Power Modules in the blocksize format are designed as base
components. The line filter is retained on the mounting surface and the Power Module is
mounted on the line filter in a space-saving fashion. The cables to the Power Modules are
already connected at the line filter. The line filter is connected to the line supply through
terminals.
Figure 3-7
Table 3- 20
Frame size
FSA
FSB
FSC
Table 3- 21
Frame size
FSA
FSB
FSC
64
PM240-2 Power Module, frame size FSA
Line filter
Shield connection
Installation example: Power Module PM240-2 (frame size FSA) with screening kit and
line filter
Connecting the line filter for the PM240-2 on the mounting surface
Connecting Power Module PM240-2 to the line filter
Fastening
4 x M4 bolts
4 x M5 bolts
Fastening
3 x M4 bolts
4 x M4 bolts
4 x M5 bolts
Manual, (GH6), 07/2016, 6SL3097-4AL00-0BP5
Tightening torque
2.5 Nm
3 Nm
Tightening torque
2.5 Nm
2.5 Nm
3 Nm
AC Drive

Advertisement

Table of Contents
loading

Table of Contents