Siemens SINAMICS S120 Manual page 285

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Overview of displays and keys
Figure 7-24
Table 7- 56
Display
Top left
2 positions
RUN
Top right
2 positions
S
P
C
Below, 6 digit
AC Drive
Manual, (GH6), 07/2016, 6SL3097-4AL00-0BP5
Control Units, Control Unit Adapters and operating components
Overview of displays and keys
Displays
Meaning
The active drive object of the BOP is displayed here.
The displays and key operations always refer to this drive object.
Is lit (bright) if the displayed drive is in the RUN state (in operation).
The following is displayed in this field:
More than 6 digits: Characters that are present but cannot be seen
(e.g. "r2" → 2 characters to the right are invisible,
"L1" → 1 character to the left is invisible)
Faults: Selects/displays other drives with faults
Designation of BICO inputs (bi, ci)
Designation of BICO outputs (bo, co)
Source object of a BICO interconnection to a drive object other than the active one.
Is (bright) if at least one parameter was changed and the value was not transferred
into the non-volatile memory.
Is lit (bright) if, for a parameter, the value only becomes effective after pressing the
P key.
Is light (bright) if at least one parameter was changed and the calculation for
consistent data management has still not been initiated.
Displays, e.g. parameters, indices, faults and alarms.
7.8 Basic Operator Panel BOP20
285