Siemens SINAMICS S120 Manual page 124

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Power Modules
4.2 Blocksize Power Modules (PM240-2)
Table 4- 27
Technical data of the PM240-2, FSE (200 V)
Line voltage 3 AC 200 ... 240 V ±10 %
Article No.
without integrated line filter
Output current
Rated current I
1)
n
Base load current I
H
for S6 duty (40 %) l
S6
Peak current l
max
Type rating
2)
based on I
n
based on I
H
Rated pulse frequency
Max. pulse frequency
Power loss
Cooling air requirement
Sound pressure level LpA (1 m)
24 V DC supply
for the Control Unit
Rated input current
4)
Resistance value of the external braking resistor Ω
Max. cable length
to braking resistor
Line supply connection L1, L2, PE
Motor connection U2, V2, W2
DC-link connection, connection for braking
resistor
DCP/R1, DCN, R2
Max. motor cable length
no EMC Category: shielded/unshielded
EMC Category C2: shielded
Weight
Rated current I
covers the load cycle for Low Overload.
1)
n
Rated power of a typical standard induction motor at 230 V 3 AC
2)
The values depend on the ambient temperature and the utilization level.
3)
The input current depends on the motor load and line impedance. The input currents apply for a load with the type rating
4)
(based on I
) for a line impedance corresponding to u
rated
124
A
A
A
A
kW
kW
kHz
kHz
kW
l/s
dB
3)
A
A
m
m
m
kg
6SL3210–
6SL3210–
1PC31-3UL0
1PC31-6UL0
130
154
104
130
156
184
208
260
37
45
30
37
4
4
8
8
1.44
1.79
153
153
56 ... 68
56 ... 68
1.0
1.0
134
158
≥ 2.5
≥ 2.5
15
15
M10 studs
Torx M8
Conductor cross-section: 35 ... 2 x 120 mm
tightening torque: 22 ... 25 Nm
Screw-type terminal
Torx M5
Conductor cross section: 25 ... 70 mm
Tightening torque: 8 ... 10 Nm
300/450