Warning Messages - Beckhoff AX2040 Assembly, Installation, Setup

Digital servo amplifier
Hide thumbs Also See for AX2040:
Table of Contents

Advertisement

Beckhoff
5.5

Warning messages

Faults which occur, but which do not cause a switch-off of the amplifier output stage (BTB/RTO con-
tact remains closed), are indicated in the LED display on the front panel by a coded warning
number.
Number
E / S / A / P Status Messages
n19-n31
* = These warning messages lead to a controlled shut-down of the drive (braking with the emergency ramp)
More information about faults and hints for removal can be found on page 96
AX2040/2070 Installation Manual
Designation
. . .
Status Message
I²t
n01
n02
regen power
n03*
S_fault
n04*
response monitoring
supply phase
n05
n06*
Sw limit switch 1
n07*
Sw limit switch 2
n08
motion task error
no reference point
n09
n10*
PSTOP
n11*
NSTOP
motor default values
n12
loaded
expansion card
n13*
n14
SinCos feedback
n15
table error
n16
Summarized warning
Fieldbus-Sync
n17
n18
Multiturn overflow
reserved
n32
firmware beta version
A
reset
02/06
Explanation
Status messages, no error, see p. 68
updating the startup configuration
I²t threshold exceeded
reached preset regen power limit
exceeded preset following error limit
response monitoring (fieldbus) has been activated
Mains supply phase missing
passed software limit switch 1
passed software limit switch 2
a faulty motion task was started
no reference point (Home) set at start of motion task
PSTOP limit-switch activated
NSTOP limit-switch activated
only for ENDAT or HIPERFACE
discrepancy between motor number saved in the encoder
and the amplifier, motor default values loaded
expansion card not operating correctly
SinCos commutation (wake & shake) not completed, will
be canceled when amplifier is enabled and wake & shake
carried out
fault according to speed/current table INXMODE 35
Summarized warning for n17 to n31
Fieldbus not synchronized
Max. number of motor turns exceeded
reserved
firmware is an unreleased beta version
RESET is present on input DIGITAL INx