Interfaces
4.9

Master-slave operation, encoder master control

This interface can be used to link several AX2040/2070 amplifiers together in
master-slave operation.
The parameters for the slave amplifiers are set up with the aid of the setup software.
The resolution (no. of pulses/turn) can be adjusted. The analog setpoint inputs are out of action.
AGND and DGND (connector X3) must be joined together !
Signal diagram (for encoders with RS422 or 24V output)
4.9.1

Connection to a AX20 master, 5B signal level (X5)

This interface can be used to link several AX20 amplifiers together in master-slave operation. Up to
16 slave amplifiers can be controlled by the master via the encoder output. The connector X5 must
be used.
Edge frequency: 1,5MHz, slew rate tv £ 0,1µs
AGND and DGND (connector X3) must be joined together !
58
AX2040/2070
02/06