Technical Description
2.15.6

Application examples

2.15.6.1

Moving single axis-groups in setting-up operation

In setting-up operation, people will frequently be within the danger zone of the machinery. Axes will
normally be moved under the control of permission switches. An additional switch-off of the unused
axes, by means of the restart lock, increases the safety margin and avoids the repeated switching
of main contactors or motor contactors.
2.15.6.2

Switching off grouped axes with separate working areas

Even when several AX2040/2070 are operating off a common mains supply and DC bus link, it is
possible to set up groups for separate working areas. These groups can then be switched off sepa-
rately for personnel safety. For this purpose, we have provided you with a suggested circuit (mains
supply circuit and control circuit for 2 separate working groups which have interconnected DC bus
links and a common mains supply voltage).
2.15.6.2.1

Control circuit

The suggested circuit fulfills safety category 1 (EN 954-1). You can fulfill safety category 3, if you
use a mains contactor with suited supervision.