Beckhoff
4.10.1
Connection to a stepper motor controller with 5V signal level (X5)
This interface can be used to connect the servo amplifier to a stepper-motor controller with 5V
signal level. The connector X5 must be used.
Edge frequency: 1.5MHz
AGND and DGND (connector X3) must be joined together !
4.10.2
Connection to stepper motor controller with 24V signal level (X3)
This interface can be used to connect the servo amplifier to a stepper-motor controller with 24V
signal level. The digital inputs DIGITAL-IN 1 and 2 at connector X3 must be used.
Edge frequency: 250 kHz
AGND and DGND (connector X3) must be joined together !
AX2040/2070 Installation Manual
AX2040/2070
AX2040/2070
02/06
Interfaces
- A.4.031.1/10,4
61