Beckhoff
4.6.6
Sine Encoder without data channel (X1)
A sine-cosine encoder without data channel can be used as standard motor feedback. Select feed-
back type 7 "SinCos 5V with W&S". Drive executes wake&shake to calculate the necessary start-up
information for the position controller every time the 24V auxiliary voltage is switched on.
The thermostat contact in the motor is connected via the encoder cable to X1 and evaluated there.
If lead lengths of more than 50m are planned, please consult our customer service.
Frequency limit (A, B): 250 kHz
Don't use this feedback type with vertical load (hanging load).
AX2040/2070 Installation Manual
02/06
AX2040/2070
Interfaces
51