Ao (Api Options); I/O Settings Commands; Cb (Commissioning Pushbutton); D0 (Dio0/Ad0) - Digi XBee-PRO S3 User Manual

900hp/xsc rf modules
Hide thumbs Also See for XBee-PRO S3:
Table of Contents

Advertisement

AT commands
Parameter Description
2
API Mode With Escapes. The device is in API mode and inserts escaped sequences to
allow for control characters. The device passes XON, XOFF, Escape, and the 0x7E
delimiter as data.
Default
0

AO (API Options)

The API data frame output format for RF packets received. This parameter applies to both the
UART and SPI interfaces.
Use AO to enable different API output frames.
Parameter range
0, 1
Parameter
Description
0
API Rx Indicator - 0x90, this is for standard data frames.
1
API Explicit Rx Indicator - 0x91, this is for Explicit Addressing data frames.
Default
0

I/O settings commands

The following AT commands are I/O settings commands.

CB (Commissioning Pushbutton)

Use CB to simulate commissioning pushbutton presses in software.
Set the parameter value to the number of button presses that you want to simulate. For example,
send CB1 to perform the action of pressing the Commissioning Pushbutton once.
See
Commissioning pushbutton and associate
See
Commissioning
Parameter range
0 - 4
Default
N/A

D0 (DIO0/AD0)

Sets or displays the DIO0/AD0 configuration (pin 20).
XBee®-PRO 900HP/XSC RF Modules
pushbutton.
LED.
I/O settings commands
94

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xbee-pro s3b

Table of Contents