Overview of the individual program parameters
70
Symbol
Parameter group
PP2 - Load mode
Load mode and position
PP3 - Deposit mode
Deposit mode and position
PP4 - Soft start
Number of stitches and speed
PP5 - Needle thread monitor
Sensitivity value for the needle thread monitor
PP6 - Thread consumption
Values for determining thread consumption
PP7 - Move
Contour is offset in a particular direction
PP8 - Scaling:
The size of the contour is changed.
PP1 - Configuration
Symbol
Meaning
Seam name
max. 20 characters
Minimum sewing foot stroke height
(min. = 1.0 .. max. = 10.0; Def. = 5.0 mm)
Sets this as the minimum value of the programmable sewing foot stroke
height so that only this value needs to be adjusted when sewing thicker
materials.
Adjusting the thread tension
(min. = 10 .. max. = 200; Def. = 100 %)
The thread tension profile for the entire contour is adjusted accordingly.
A value of 100 % means that no adjustments are made.
Adjust empty-run speed
(min. = 10 .. max. = 200; Def. = 100 %)
The forwarding speeds are adjusted accordingly.
Clamp ID code
Barcode (ID code) of max. 10 characters for performing a safety check
before the start of sewing (the barcode reader additional equipment must
be activated)
Laser marking lamps
Up to four laser marking lamps for easier alignment of the sewing material
can be controlled (the additional equipment must be activated)