DURKOPP ADLER 906 Operating Instructions Manual page 129

Hide thumbs Also See for 906:
Table of Contents

Advertisement

Troubleshooting
Error code
2356
Machine control
3100
3102
3103
3107
3109
3121
3123
3210
3215
3220
3500
3501
3502
3721
3722
4201
5301
Operating Instructions 906 - 02.0 - 11/2016
Description
Stroke position stepper motor
overtemperature
• Feed system not moving freely
• Stepper motor faulty
• Control defective
Machine control voltage
• Temporary mains voltage
interruption
Machine voltage in sewing motor
intermediate circuit
• Temporary mains voltage
interruption
Machine voltage in stepper motor
intermediate circuit
• Temporary mains voltage
interruption
Machine temperature
• Ventilation openings closed
• Ventilation grille dirty
Threading mode is switched on
Inadequate air pressure
Oil sensor active
Thread broken
Bobbin empty (remaining thread
counter)
Bobbin empty (remaining thread
counter)
Error in calculating the contour data • Reload the contour data
Target position of the XY clamps
outside the motion limits
Target position of the XY clamps
within the "forbidden areas"
Internal error
Internal CF card defective
Program cannot be sewn
Troubleshooting
• Eliminate sluggishness
• Replace the stepper motor
• Replace the control
• Check the mains voltage
• Check the mains voltage
• Check the mains voltage
• Clean ventilation grille
• Check ventilation openings
Switch off threading mode  p. 17
Turn up air pressure and stabilize
Top off the oil  p. 97
Re-thread the thread
Insert full bobbin  p. 29
Insert full bobbin  p. 29
• Check the contour data  p. 60
Adjust the contour data
Adjust the contour data
• Switch off and on the machine
• Software update
• Notify DA Service
• Switch off and on the machine
• Retrofit/replace control
Copy program to DAC  p. 63
127

Advertisement

Table of Contents
loading

Table of Contents