Time Unit Setting; Output T/S + Id - IDTECK LX505 User Manual

Proximity / pin access controller
Hide thumbs Also See for LX505:
Table of Contents

Advertisement

2.3

Time Unit Setting

This setting allows you to define the unit of time.
1sec
Output Time is calculated in the time unit of 1 second for the IN/OUT definition.
0.1sec
Output Time is calculated in the time unit of 1/10 second (or 100ms) for the IN/OUT
definition
e.g.
If you want to activate the Door Relay (Relay #1, DR) for 3 seconds, appropriate setting
values are as follows;
The Time Unit should be set to 1 SEC.
The Door Relay (DR) Output Time should be set to "03".
If you want to activate Door Relay (Relay #1, DR) for 0.5 second, appropriate setting val
ues are as follows;
The Time Unit should be set to 0.1 SEC.
The Door Relay (DR) Output Time should be set to "05".
2.4

Output T/S + ID

F2 SETUP MENU
p.43