5.3 Device Setting

5.3.1 26Bit / 34Bit Wiegand Setting
Select the data format (26bit/34bit) input to reader port. There is a switch for bit setting on the upper left side of
iCON100 board. The switch is set to 'OFF' position as the default (26Bit Wiegand setting). If the switch is set
to 'ON' position as shown below table, the system is set to 34Bit Wiegand.
 26bit Wiegand type format: Using 26bit Wiegand format reader (RF10, 20, 30, 70 RFK101.)
 34bit Wiegand type format: Using 34bit Wiegand format reader (SR10, 20, 30 SRK101)
If DIP switch turns from 'ON' to 'OFF' or 'OFF' to 'ON', buzzer is generated. If the buzzer doesn't stop after the
DIP switch is changed, it means ID information or event is stored in the memory. In this case, delete existing
ID and event by initialization then you can change data type of reader port.
Switch for 26/34Bit Wiegand Setting
Figure: Position of 26/34Bit Wiegand Setting Switch
26Bit Wiegand (Default)
34Bit Wiegand
Figure: 26Bit/34Bit Wiegand Setting Example