☞ The unit suddenly returns from Setup Mode to normal operating mode.
Cause
Solution
☞ The buzzer keeps beeping; "beep~ beep ~ beep" or "beeeeeeeep~~~~".
Cause
Solution
☞ The "SCHEDULE ERROR" message appears when an RFID card is read.
Cause
Solution
p.80
Appendix
- Press <F2> key.
- [LANGUAGE] will appear on the LCD, then use the <6> key to choose [RD
1_PIN_INPUT] and press [ENT] key to modify the value to 'USE' by using <4
> or <6> key.
2. When there is no beep sound or the problem persists after the keypad h
as been enabled, contact a designated service center.
Time-out error
The LX505 is originally programmed to go back to the normal operating m
ode when no keys are pressed or no cards are read within 60 seconds.
An error in the Installation, Door status or Internal circuits.
1. Check the door status. It occurs when the door is opened over 3 sec (De
fault).
2. Check the door contact sensor type: it must be NO/NC-type.
3. Check the 10 Time schedule code (01~10) values of output T/S, in [7. O
UTPUT T/S] of F6 Setup Menu. This problem can occur if the time schedule
code is set between 01 and 10 and the present time is within the time zon
e of the selected schedule. If the wrong time schedule is selected, cancel it
by assigning the blank time schedule code "00"
4. Check the Tamper switch of the LX505.
5. If the trouble persists after checking the above, contact a designated ser
vice center.
An error in RFID card registration, time schedule setting or the system itself.
1. If the LX505 used to be properly operating before, it is likely that there h
as been an electric shock that damaged the internal memory and data. Ple
ase initialize the unit as instructed in the manual.
2. Check if the ID information has been configured incorrectly.
Register ID again and check the following points.
- In order to restrict access of a user within a specific time zone as instructe
d in the manual, register time schedule in advance and apply the time sche
dule code(1~10) to the user during the registration process.
- In order to allow the user to access at all times, enter "00".
3. Use the software for time schedule settings if the LX505 is connected to
a PC. Refer to the software manual for more details.
4. If the trouble persists after checking the above, contact a designated ser

Advertisement