This setting is related to the Output Time Schedule setting of [F5 SETUP MENU]. The Output
Time Schedule setting can be used to generate outputs for a certain assigned period of time,
for example to keep the door open during that time. By setting this Output T/S + ID setting t
o USE, you can delay the output (e.g. door opening) until the first access after the time sche
dule period begins. If there is no access during the assigned period, no output will be gener
ated.
NOT USE
Output is generated at the beginning of the assigned Time Interval.
USE
Output is generated when a registered user gains access for the first time after the Ti
me Interval of the applied Time Schedule begins.
The default setting is NOT USE
2.5

Anti-passback Mode

The Anti-pass back feature is used to prevent an identical user from entering or exiting the d
oor more than twice in a row. This mode can be applied only when an Exit Reader is installe
d. DO NOT set this mode to USE if an Exit Button is installed instead of an Exit Reader.
NOT USE
The Anti-pass back feature is disabled.
USE
The Anti-pass back feature is enabled.
ALL CLEAR
All Anti-pass back flags are reset, and access will be allowed one time regardless of th
e current status of the existing flags.
p.44