3.3
Arm/Disarm Setting
This setting allows you to set the Arm Code and the Disarm Code. After setting the Arm Cod
e or Disarm Code, you can set the LX505 to the ARM mode by entering the ARM code and
presenting an ARM/DISARM card (i.e. a card that was registered with Code 3). Once the LX
505 toggles into ARM mode, all readers freeze and stop reading cards. To DISARM the LX50
5, enter the Disarm Code and present an ARM/DISARM card.
The ARM Code, DISARM Code, and Duress Code must all differ.If ARM/DISARM co
des are both 00, Arm/Disarm function does not work.
3.4
Two Men Mode
To apply this feature, cards designated for guides should be registered into the Guide Group
(C:1) and visitor cards into the Visitor Group(C:2). If configured in the two-man mode, the L
X505 won't grant access until one guide card and one visitor card are presented together wi
thin a certain time length.
F3 SETUP MENU