Duress Mode; Wiegand Output - IDTECK LX505 User Manual

Proximity / pin access controller
Hide thumbs Also See for LX505:
Table of Contents

Advertisement

2.6

Duress Mode

You can set Duress Mode for Reader#1. The default setting is NOT USE. If you select USE, th
e LCD will display the default Duress Password '00'. If you want to change the Duress Passw
ord, press <ENT> key and enter a 2-digit Duress Password. If you do not want to change it, p
ress the <ESC> key.
In case of duress, enter the 2-digit Duress Password and press <ENT> key prior to p
resenting the card. The Duress Alarm will be generated and reported to the host P
C while the door is opened as usual.
The Duress Password and ARM and DISARM codes must differ.
2.7

Wiegand Output

This feature allows you to use the LX505 as a reader (as opposed to as a controller). If this se
tting is set to USE, the LX505 sends 26bit Wiegand Output through two TTL output ports. (T
he LX505SR sends out 34bit Wiegand output.)
F2 SETUP MENU
p.45