INSTALLATION
OPERATION TEST OF THE LAWNMOWER
Test the following points by using the TEST SET UP program (page 3-34), after the working mode set up.
• Return test with HOME TEST MODE (Put the lawnmower on the centre of the zone and start the test).
• Running test at the installed zone (Start from the docking station).
If the lawnmower cannot reach the specified zone or cannot return to the docking station, there is possibility that settings of the
zone shape, sensitivity of the boundary wire signal (page 3-9) or the passage width do not match the layout of the lawn (page 3-10).
Change these settings and perform the TEST SET UP program again.
BOUNDARY WIRE
DOCKING STATION
A
A
The sensitivity level
does not fit the
mowing zone = The
mower cannot receive
the boundary wire
signal.
Passage width is inside
of the receivable range
of the boundary wire
signal.
Passage width is inside of the receivable range of the station signal.
3-14
C
B
PASSAGE WIDTH
B
Passage width is too wide. The lawnmower
B
cannot detect the station signal.
C
LAWNMOWER
C
C
Two possibilities:
1.The sensitivity level does
not fit the mowing zone.
2.The passage width is too
wide or width between both
wire is too narrow and the
lawnmower cannot detect
the boundary wire signal
correctly. = The lawnmower
cannot run along the
boundary wire exactly.
The area size, the setting of
the sensitivity level and
passage width are balancing.
OK
NG