INSTALLATION
PLANNING THE MOWING ZONE
CHECK THE MOWING ZONE CONDITION
• Confirm that the height of the grass is 7cm or less. If the grass is taller than 7cm, cut the grass using a standard lawnmower.
• Do not lay boundary wire so that it intersects on a slope of more than 10 degrees (17%). You can lay boundary wire parallel to a
slope of more than 10 degrees (17%) in order to access an area with a slope of less than 10 degrees(17%).
FIX THE LOCATION OF THE DOCKING STATION
• The docking station must be installed at an inclination of no more than 5 degrees (8.7%).
5 degrees (8.7%)
5 degrees (8.7%)
• The docking station must not be curved.
• Prefer shading area to install the docking station.
• The boundary wire must extend in a straight line 250 cm from both the front and rear of the docking station.
• There must not be foreign objects within the mowing area near the docking station (in the shaded area indicated in the image).
• The transformer must be placed where it is well ventilated and under the roof.
3-6
7 cm or less
More than 10
degrees (17%)
Less than 10
degrees (17%)
300 cm
250 cm
250 cm
5 degrees (8.7%)
5 degrees (8.7%)