SMA Solar Technology AG
Error no. Explanation
6452
Measured AC voltage of the utility
grid is less than inverter voltage.
6453
AC voltage of grid limit monitoring
is faulty.
6454
AC current is faulty.
6455
AC voltage is faulty.
6456
Pre-charging circuit of DC link is
defective.
6457
Capacitor self-test has failed.
6461
Insulation monitoring device has
not adopted threshold.
6471
Online capacitor self-test has
failed.
6472
Endless loop between online and
offline capacitor test
6501
Interior temperature of inverter is
too high.
6502
Temperature of inverter bridge is
too high.
6508
Outside temperature is too high.
6605
The fast stop was tripped due
overtemperature in the switch cabi-
net.
7001
Cable break or short circuit at in-
verter temperature sensor
7002
7004
7006
7501
Interior fan is defective.
7502
7503
Inverter bridge fan is defective.
7507
Motor-protective circuit breaker of
fan has tripped.
7510
Interior fan is defective.
System Manual
Inverter behavior
Corrective measures
S1
S2
R
W
W
• Contact Service partner.
W
W
• Contact Service partner.
W
W
• Contact Service partner.
W
W
• Contact Service partner.
W
W
• Contact Service partner.
Q
Q
• Contact Service partner.
15
15
x
• Check the insulation monitoring device
min
min
Q
Q
x
• Contact Service partner.
Q
Q
x
• Contact Service partner.
30 s
1 min ‒
• Check function of the fans.
• Clean the fans.
30 s
1 min ‒
• Clean clogged fan inlets and ventilation
30 s
1 min ‒
30 s
1 min ‒
• Contact Service partner.
W
W
• Check the wiring of the temperature
W
W
• Contact Service partner.
W
W
W
W
W
W
• Check function of the fans.
• Clean the fans.
W
W
• Clean clogged fan inlets and ventilation
W
W
W
W
W
W
9 Troubleshooting
and cabling.
plates.
sensor.
plates.