Installing INADS (Initialization and Administration System) Interface
Requirements
The Initialization and Administration System (INADS) trunk should be specified to appear
on the twenty-fifth pair of an RJ21X network interface jack. The INADS trunk must be a
two-way, rotary dial, loop start trunk. The INADS trunk is connected to the TN731
Maintenance circuit pack through the Trunk/Auxiliary Field. This connection is made at the
INADS terminals. Figure 3-95 shows a typical INADS trunk installation.
Installation
1 . Determine INADS trunk appearance in the green Trunk/Auxiliary Field.
2 . Install jumpers between INADS trunk appearance (IN) and INADS terminals.
3 . Label terminals for INADS trunk appearance (IN).
Figure 3-97. Connections at Trunk/Auxiliary Field for INADS Trunk
110-TYPE HARDWARE