66-TYPE HARDWARE
Installing 66-Type Hardware at Satellite Locations
To install the 66-type connecting blocks at the satellite location, use the same installation
procedure described under the heading Installing the Cross-Connect Field. Figure 4-46
shows a typical satellite location layout.
Figure 4-46. Typical Satellite Location Layout
Three-pair station circuits are run from the equipment room to the satellite closet white
field and four-pair station circuits are run from the satellite closet blue field to the
information outlets. Connections to both the three- and four-pair circuits can be made with
connectorized or field-terminated cables depending on the type of connecting blocks used.
Labeling
Figure 4-46 shows the fill directions for the blue and white fields at the satellite location.
The labeling for the lead designations is written on the connecting blocks using a permanent
felt-tipped pen as described under Labeling the Cross-Connect Field.
Installing 4-Pair Station Cables
The 4-pair station cables can either be plugged into the adapters or field-terminated at the
cross-connect field or satellite closet and run to the information outlet locations.
Installing the Information Outlets
Install the information outlets (Figure 4-47) at the terminal locations. See Table 4-I for
wiring information.
4 - 7 4