AT&T 75 Wiring Manual page 558

Hide thumbs Also See for 75:
Table of Contents

Advertisement

66-TYPE HARDWARE
Installation—Non-FCC Registered Music Source
1.
Determine port assignment of feature from Feature-Related System Parameters
Form:
2 .
Identify carrier slot and label both ends of an A25D cable.
3 .
Run and connect A25D cable from assigned port carrier slot to 25-pair connector
on auxiliary cabinet's ED-1E443-10 Intra-Connection Panel (see Figure 4-85).
4 .
Run and connect B25A cable from 25-pair connector on ED-1E443-10 Intra-
Connection Panel to switch side of cross-connect field (see Figure 4-85).
5.
Write lead designations on 66-type connecting block in the yellow field using a
permanent felt-tipped pen.
Mount 36A voice coupler.
6.
7.
Remove cover from 36A voice coupler and make connections to 110-type wiring
blocks on ED-1E443-10 Intra-Connection Panel (see Figure 4-85).
8.
Connect output of 2012D transformer to AC and ACG terminals on 36A voice
coupler.
9.
Plug 20l2D transformer into 117-volt power outlet not under control of a wall
switch.
10.
Install cover on 36A voice coupler.
11.
Install jumper wires at cross-connect field.
12.
Install music source per manufacturer's instructions.
13.
Connect 2-pair line cord (modular plug at one end) from information outlet to
music source (see Figure 4-85).
14.
Administer per AT&T System 75 and System 75 XE Implementation and A T & T
System 75 and System 75 XE Administration.
4-132
EXAMPLE:
Port Number
02
01
B
Carrier
Slot
Circuit

Advertisement

Table of Contents
loading

This manual is also suitable for:

75 xe