Programming for 4100SM

1✳40 & 1✳41 Date and Time Set Report Codes
1✳70 Event Log Types (1=enable; 0=disable
1✳71 12/24-Hour Time Stamp (0=12 hr; 1=24 hr)

Programming for Access Control

A user can trigger an access point (i.e., door strike) for 2
seconds by entering User Code + [0].
To program the VISTA-40 for access control, perform
the following steps:
Step
Action
1
Enter Relay Programming in the #93 Menu
Mode.
2
Program the relay type as 1, or 2.
3
For type 1, program the ECP address and
relay number.
4
For type 2, program the house and unit codes.
5
Program the relay number in field 1∗76
(partition-specific).
See Relay Programming in the Programming Guide for
a detailed explanation.