Sensor settings (2)
Pipe settings
No
Sensor settings
Text
Pipe settings
Pipe class
Pipe size
Pipe circumference
Outer pipe diameter
Wall thickness
Select material
Wall sound velocity
SITRANS FST030 (Modbus)
Operating Instructions, 08/2018, A5E37367739-AD
Yes
Pipe class
Pipe size
Custom
Outer diameter + wall thickness
Circumference + wall thickness
Pipe circumference
Options/Description
Select "Yes" to configure the pipe.
Select the pipe class.
Select the pips size from the options available for the selected pipe class.
Enter pipe circumference. Only available if custom pipe class is selected.
Enter outer pipe diameter. Only available if custom pipe class is selected.
Enter wall thickness. Only available if custom pipe class is selected.
Select the pipe material.
Enter the wall sound velocity of the material. Only available if custom
material is selected.
Commissioning
6.6 Commissioning via local display
Outer pipe diameter
Wall thickness
Select material
Custom
Wall sound velocity
1)
Pipe expansion
Liner
Yes
No
Liner material
Liner settings
Disturbed flow
Inner pipe roughness
1)