Siemens SITRANS F Series Operating Instructions Manual page 116

Ultrasonic flowmeters
Hide thumbs Also See for SITRANS F Series:
Table of Contents

Advertisement

Diagnostics and troubleshooting
9.8 Fault codes and corrective actions
ID/
Diagnostic
Icons
229
Sound velocity
230
Sound velocity
231
Sound velocity
232
Flow velocity
233
Flow velocity
234
Flow velocity
235
Flow velocity
236
Pressure
237
Pressure
116
Action
Value above warning limit. Check process con‐
ditions or align limit to normal operation. Adjust
parameter "Upper warning limit"
Value below warning limit. Check process con‐
ditions or align limit to normal operation. Adjust
parameter "Lower warning limit"
Value below alarm limit. Check process condi‐
tions or align limit to normal operation. Adjust
parameter "Lower alarm limit"
Value above alarm limit. Check process condi‐
tions or align limit to normal operation. Adjust
parameter "Upper alarm limit"
Value above warning limit. Check process con‐
ditions or align limit to normal operation. Adjust
parameter "Upper warning limit"
Value below warning limit. Check process con‐
ditions or align limit to normal operation. Adjust
parameter "Lower warning limit"
Value below alarm limit. Check process condi‐
tions or align limit to normal operation. Adjust
parameter "Lower alarm limit"
Value above alarm limit. Check process condi‐
tions or align limit to normal operation. Adjust
parameter "Upper alarm limit"
Value above warning limit. Check process con‐
ditions or align limit to normal operation. Adjust
parameter "Upper warning limit"
Comment
SITRANS FST030 (Modbus)
Operating Instructions, 08/2018, A5E37367739-AD

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sitrans fst030

Table of Contents