Siemens SITRANS F Series Operating Instructions Manual page 181

Ultrasonic flowmeters
Hide thumbs Also See for SITRANS F Series:
Table of Contents

Advertisement

Modbus
Data type /
register
Size in bytes
1124
Float / 4
1126
Float / 4
1128
Float / 4
1130
Float / 4
1132
Float / 4
1134
Float / 4
1136
Float / 4
1138
Float / 4
1140
Float / 4
1142
Float / 4
SITRANS FST030 (Modbus)
Operating Instructions, 08/2018, A5E37367739-AD
Parameter
Description
Calibration val‐
Calibration correction
ue 14
factor that is associ‐
ated to Calibration
point 14.
Calibration
Calibration point 15 for
point 15
undirectional flow or
calibration point 15 for
bidirectional positive
flow.If 0.0 the calibra‐
tion point is not used.
Calibration val‐
Calibration correction
ue 15
factor that is associ‐
ated to Calibration
point 15.
Calibration
Calibration point 16 for
point 16
undirectional flow or
calibration point 16 for
bidirectional positive
flow. If 0.0 the calibra‐
tion point is not used.
Calibration val‐
Calibration correction
ue 16
factor that is associ‐
ated to Calibration
point 16.
Calibration
Calibration point 17 for
point 17
undirectional flow or
calibration point 17 for
bidirectional positive
flow. If 0.0 the calibra‐
tion point is not used.
Calibration val‐
Calibration correction
ue 17
factor that is associ‐
ated to Calibration
point 17.
Calibration
Calibration point 18 for
point 18
undirectional flow or
calibration point 18 for
bidirectional positive
flow. If 0.0 the calibra‐
tion point is not used.
Calibration val‐
Calibration correction
ue 18
factor that is associ‐
ated to Calibration
point 18.
Calibration
Calibration point 19 for
point 19
undirectional flow or
calibration point 19 for
bidirectional positive
flow. If 0.0 the calibra‐
tion point is not used.
A.9 Modbus holding registers tables
Default value
Value range /
[units]
Setting options
(units register)
1.0
0.5 - 2.0
0.0
0.0 - 100000.0
[m
/s]
3
(7500)
1.0
0.5 - 2.0
0.0
0.0 - 100000.0
[m
/s]
3
(7500)
1.0
0.5 - 2.0
0.0
0.0 - 100000.0
[m
/s]
3
(7500)
1.0
0.5 - 2.0
0.0
0.0 - 100000.0
[m
/s]
3
(7500)
1.0
0.5 - 2.0
0.0
0.0 - 100000.0
[m
/s]
3
(7500)
Modbus communication
Access
level
Read /
write
(Expert)
Read /
write
(Expert)
Read /
write
(Expert)
Read /
write
(Expert)
Read /
write
(Expert)
Read /
write
(Expert)
Read /
write
(Expert)
Read /
write
(Expert)
Read /
write
(Expert)
Read /
write
(Expert)
181