Parameter Lists

5.1.13 16-** Data Readouts

Par.
Parameter description
No. #
16-0* General Status
16-00
Control Word
16-01
Reference [Unit]
16-02
Reference [%]
16-03
Status Word
16-05
Main Actual Value [%]
16-09
Custom Readout
16-1* Motor Status
16-10
Power [kW]
16-11
Power [hp]
16-12
Motor Voltage
16-13
Frequency
16-14
Motor Current
16-15
Frequency [%]
16-18
Motor Thermal
16-3* Drive Status
16-30
DC Link Voltage
16-34
Heatsink Temp.
16-35
Inverter Thermal
16-36
Inv. Nom. Current
16-37
Inv. Max. Current
16-38
SL Controller State
16-5* Ref. & Feedb.
16-50
External Reference
16-52
Feedback[Unit]
16-6* Inputs & Outputs
16-60
Digital input
16-61
Terminal 53 Setting
16-62
Analog Input AI53
16-63
Terminal 54 Setting
16-64
Analog Input AI54
16-65
Analog Output AO42 [mA]
16-66
Digital Output
16-71
Relay Output [bin]
16-72
Counter A
16-73
Counter B
16-79
Analog Output AO45
16-8* Fieldbus & FC Port
16-86
FC Port REF 1
16-9* Diagnosis Readouts
16-90
Alarm Word
16-91
Alarm Word 2
16-92
Warning Word
16-93
Warning Word 2
16-94
Ext. Status Word
16-95
Ext. Status Word 2
VLT HVAC Basic Drive Programming Guide
Default value
0 N/A
0.0 ReferenceFeedbackUnit
0.0 %
0 N/A
0.0 %
0.0 CustomReadoutUnit
0.00 kW
0.00 hp
0.0 V
0.0 Hz
0.00 A
0.0 %
0.0 %
0 V
0 °C
0.0 %
0.0 A
0.0 A
0 N/A
0.0 %
0.0 ProcessCtrlUnit
0 N/A
[0] Current mode
1.000 N/A
[0] Current mode
1.000 N/A
0.000 mA
0 N/A
0 N/A
0.0 N/A
0.0 N/A
0.000 mA
0 N/A
0.0 N/A
0.0 N/A
0.0 N/A
0.0 N/A
0.0 N/A
0.0 N/A
®
MG.18.B1.02 - VLT
is a registered Danfoss trademark
2-set-up
Change
Conver-
during
sion index
operation
1 set-up
TRUE
0
1 set-up
TRUE
-3
1 set-up
TRUE
-1
1 set-up
TRUE
0
1 set-up
TRUE
-2
1 set-up
TRUE
-2
1 set-up
TRUE
-3
1 set-up
TRUE
-3
1 set-up
TRUE
-1
1 set-up
TRUE
-1
1 set-up
TRUE
-2
1 set-up
TRUE
-1
1 set-up
TRUE
0
1 set-up
TRUE
0
1 set-up
TRUE
100
1 set-up
TRUE
0
1 set-up
TRUE
-2
1 set-up
TRUE
-2
1 set-up
TRUE
0
1 set-up
TRUE
-1
1 set-up
TRUE
-3
1 set-up
TRUE
0
1 set-up
TRUE
1 set-up
TRUE
-2
1 set-up
TRUE
1 set-up
TRUE
-2
1 set-up
TRUE
-2
1 set-up
TRUE
0
1 set-up
TRUE
0
1 set-up
TRUE
0
1 set-up
TRUE
0
1 set-up
TRUE
-2
1 set-up
TRUE
0
1 set-up
TRUE
0
1 set-up
TRUE
0
1 set-up
TRUE
0
1 set-up
TRUE
0
1 set-up
TRUE
0
1 set-up
TRUE
0
Type
uint_16
Int32
Int16
uint_16
Int16
5
5
Int32
Uint32
Uint32
Uint32
Uint32
Uint16
uint_16
uint_8
Uint32
uint_8
uint_8
uint_16
uint_16
uint_8
Int16
Int32
Uint16
-
Uint8
Uint16
-
Uint8
Uint16
Uint16
VisStr[4
]
Uint16
Int16
Int16
Uint16
Int16
uint_32
uint_32
uint_32
uint_32
uint_32
uint_32