Log in to the CLI management system. For details, see eSpace IAD Product
Documentation.
Step 1 Set the IP address or domain name of the UCEMS server.
Issue 10 (2019-04-09)
5

Configuration (EMS)

If multiple IADs are available on the network, you can use the
Unified Communication Element Management System
(UCEMS) to configure all IADs. To use the UCEMS to
configure and upgrade IADs in a unified manner, you must set
the UCEMS connection parameters on IADs.
You can run the nms primary command to set the IP
address of the UCEMS server. For example:
TERMINAL(config)#nms primary 192.168.1.201
If two UCEMS servers are available on the live network, you
can run the nms primary ip-addresssecondary ip-address
command to set the IP addresses of both UCEMS servers. The
two servers will work in the active and standby mode. For
example:
TERMINAL(config)#nms primary 192.168.1.201 secondary
192.168.1.55