Item
Control protocol
used between the
IMS and the
IAD
IP address of the
SBC server
IP address of the
IAD
SIP signaling
port number on
the IAD
SIP signaling
port number on
the IAD
Domain name of
the IAD
Issue 10 (2019-04-09)
Table 4-5 Connection data between the IAD and the IMS
Value
SIP protocol
192.168.1.40/255.25
5.255.0
192.168.1.62/255.25
5.255.0
5060
5060
abc.example.com
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4 Manual Configuration (CLI)
Parameter and Value on
the IAD
Protocol mode: SIP
IP address of the SIP
server: 192.168.1.40
NOTE
The IP address of the SIP
server is the IP address of the
P-CSCF or SBC. Set the
parameter based on the site
requirements.
IP address of the IAD:
192.168.1.62/255.255.255.
0
NOTE
The IAD must be able to ping
the SIP server.
Server port number: 5060
Local port number: 5060
User domain name:
abc.example.com
NOTE
The user domain name must
be unique.